Feed Performance Computing Form

Values ​​of the displayed performance graph and performance table
may not be satisfied due to the load on the feeder due to material stress etc.

Input basic conditions ...

Model :
Feed Angle を指定
Feed Angle [deg] :
*Max 4 types ... Please enter in the range of 1~300.
Press Speed [spm] :
*Specify the range to be displayed.
Feedable Time を指定
Feedable Time [ms] :
*Specify the range to be displayed.

Enter optional conditions ...

Comparative Model :
Target Feed Length [mm] :

Model TJ06 Specifications

Max. Press Rotational Speed [spm] 200
Max. Feed Speed [mm/s] 1442

Required Release Operation Angle

Model TJ06 at 200spm
  1. The actual release start / end timing does not match the input signal. Timing will change due to adjustment of air pressure, pressurized spring load, release stroke amount, etc.
  2. The input signal should continue for a period longer than the angle shown in green on the graph. The standard value of the product is displayed, and when you change the noise filter strength, the value will be different.
  3. Because the actual operation time varies greatly depending on usage conditions, only the minimum time constraint of the above input signal is displayed. In consideration of the delay time of the release end, a margin is required until the feed start timing.

Model TJ06 Performance Graph

Chart Manipulation Method
  • Double click : Zoom out.
  • Drag vertically or horizontally : Zoom specified area.
  • Hold down Shift key and drag : Move zoomed area.

X Axis :
Y Axis :

Model TJ06 Performance Table

Row Step Value

Press Speed
[spm]
Max. Feed Length[mm]
TJ06
150°180°210°
20021.031.945.0
18026.740.456.7
16034.952.473.4
14047.070.297.9
12066.097.9136.0
10097.9144.4200.0
80157.4231.1318.1
60288.1408.3528.5
40588.7769.0949.4
20999.9999.9999.9